Adaptive Dancer Position ControllerRSD200 & RSD200PWEB CONTROL PRODUCTSUser ManualFORM NO. L-21161-E-0108
FORM NO. L-21161-E-010810Figure 7 Table 1Designation Color FunctionI1 Green "ON when +5 VDC is presentI2 Green "ON" when +12 VDC is pre
11FORM NO. L-21161-E-0108The RSD200 determines the start/stop state of a machine through the Start/Stopped Signal Input. The RSD200 was designed to ac
FORM NO. L-21161-E-010812Determine which signal type your machine uses and set the Rotary Selection Switch (See Figures 7 & 8).Table 2Start Only S
13FORM NO. L-21161-E-01082.0 COMMUNICATIONS SOFTWARE SETUPFigure 102.1 TORQUE ACTUATOR Select the type of actuator the RSD200 will control “pneumatic
FORM NO. L-21161-E-0108143.2 WEB TENSION - RSD200P ONLYIf the machine’s tension setpoint varies more than +/- 50%, RSD200 performance can be improved
15FORM NO. L-21161-E-0108Most applications only require adjustment of GAIN and NEW ROLL ADAPTATION to tune the RSD200. For extreme applications, the
FORM NO. L-21161-E-010816For most applications the Basic Tuning Parameters will be sufficient to tune the RSD200. The Advanced Tuning Parameters are fo
17FORM NO. L-21161-E-01085.0 OPERATIONManual control of the RSD200 OUTPUT can be achieved by pressing the SWITCH TO MANUAL CONTROL button on the diagn
FORM NO. L-21161-E-010818A typical unwind application begins with a new full roll. To insure that the dancer arm stabilizes as quickly as possible, th
19FORM NO. L-21161-E-0108A typical winding application begins at core. To insure that the dancer arm stabilizes as quickly as possible, the RSD200 sho
FORM NO. L-21161-E-01082Nexen Group, Inc.560 Oak Grove ParkwayVadnais Heights, Minnesota 55127ISO 9001 CertifiedIn accordance with Nexen’s established
FORM NO. L-21161-E-0108206.0 DIAGNOSTICS5.4 SPLICEThe RSD200 utilizes “Smart Splicing” which means that rolls of different sizes can be loaded or spli
21FORM NO. L-21161-E-01089.0 SERVICE INSTRUCTIONSNexen does not recommend customer servicing of this product. Contact Nexen for replacement parts or
FORM NO. L-21161-E-01082210.0 TROUBLESHOOTINGProblem Possible Cause Quick Test Corrective ActionGreen LEDs are not lit.No power to RSD200boardPlace th
23FORM NO. L-21161-E-010811.0 APPENDIX RS232 Communications can be used to broadcast Diagnostic Parameters from the RSD200 to a device such as a PLC o
FORM NO. L-21161-E-01082412.0 WARRANTYWarrantiesNexen warrants that the Products will be free from any defects in material or workmanship for a period
3FORM NO. L-21161-E-0108TABLE OF CONTENTSINTRODUCTION ------------------------------------------------------------------------------------------------
FORM NO. L-21161-E-01084POWERSUPPLYCUSTOMER SUPPLIEDCUSTUMERAIR SUPPLYE/PorI/PFILTERRSD200OPTIONALPLCBrake,Clutch,or DrivePositionSensorINTRODUCTIONTh
5FORM NO. L-21161-E-01081.1 INSTALLATIONThe RSD200 can be mounted horizontally or vertically near the pneumatic tension brake or clutch. Provide enoug
FORM NO. L-21161-E-01086+24 VDC & DC Common: RSD200 requires 24 VDC to operate (Refer to SPECIFICATIONS for current rating).Sensor Excitation: T
7FORM NO. L-21161-E-0108RSD200PINKORANGEYELLOWPURPLEGRAYREDBLACKWHITEGREEN24VPower Supply+_Arm PositionSensorSignal+24Vcom+_Start/StoppedSpliceControl
FORM NO. L-21161-E-01088RSD200PINKORANGEYELLOWPURPLEGRAYREDBLACKWHITEGREEN24VPower Supply+_Arm PositionSensorSignal+12VcomNexenDPS30,DPS 60orMechanica
9FORM NO. L-21161-E-01081.4 RSD200P PNEUMATIC CONNECTIONSNexen developed the RSD200P for applications that would benefit from tension setpoint compensa
Comments to this Manuals