FORM NO. L-21082-E-0110
7
3/2 (3 Way)
4/2 (4 Way)
5/2 (4 Way)
5/2 (5 Way)
AIR CONNECTIONS
NOTE
For quick response, Nexen recommends a quick
exhaust valve and short air lines between the
Control Valves and the product. Align the air inlet
ports to a down position to allow condensation to
drain out of the air chambers of the product.
CAUTI ON
Low air pressure will cause slippage and
overheating. Excessive air pressure will
cause abrupt starts and stops, reducing
product life.
All Nexen pneumatically actuated devices require clean
and dry air, which meet or exceeds ISO 8573.1:2001
Class 4.4.3 quality.
Air Pressure (Gage) Limits
6.9 Bar (120 PSI) Absolute Max.
0 Bar (0 PSI) Absolute Min.
The following are common air supply schemes used with
this product. These are examples and not an all-inclusive
list. All air circuits to be used with this product must be
designed following EN983 guidelines.